Package com.tccc.kos.ext.freestyle.hardware.can.troubles
package com.tccc.kos.ext.freestyle.hardware.can.troubles
-
ClassesClassDescriptionBase class for various AirVentAware flow errors.BasePumpTrouble<T extends com.tccc.kos.ext.dispense.Pump>Base class for all pump troubles.CANPumpTrouble<T extends AbstractCANPump>Base class for all CAN pump troubles.Trouble indicating CGP no flowTrouble that indicates that the version of CGPPump installed is not supported on this device.Flow below error threshold.When macksm fails to read FCM EEPROM (and use the default FCM cal value) Event sequence: 121 - JET_ST_FCM_CAL_DEFAULT_VAL_USEDFCM failed to stop.Flow over error threshold.FCM gear meter encoder failure Event sequence: 83 - JET_ST_FCM_GEAR_METER_ENC_FAILURENo flow detected for hfcs (so we can have different messaging) Event sequence: 89 - JET_ST_FCM_NO_FLOWFCM detected high pressure.FCM failed to home.FCM detected low pressure.No flow detected.Pump is delivering at a higher rate than requested.Flow over error threshold.Base trouble for flow meter related troubles.FCM base trouble that causes the board to be rebooted.Trouble that indicates that fcm is sold out.FCM step motor encoder failure Event sequence: 84 - JET_ST_FCM_STEP_MOTOR_ENC_FAILUREFCM step motor is jammed.FCM step motor is no longer jammed.Unexpected flow detected.Unexpected high flow rate detected.Unexpected slow flow rate detected.Pump is delivering at a lower rate than requested.FCM detected low pressure.FCM failed to reset.FCM failed to start.FCM failed to stop.Occurs on I2C MUX Reset Peripheral (same as cal value err 122) Event sequence: JET_ST_I2C_MUX_BUSY_RESET(123)Trouble that indicates that LFCV is sold out.Pumping air, no ingredient left.No current sense on the pump.Micro Pump Default cal value used Event sequence: JET_ST_MICRO_PUMP_DEFAULT_CAL_USED(122)Fuel gauge hit -30 ml within the pump.Pump is occluded.NNS not available due to sold out.Pump is delivering at a higher rate than requested.Pump is occluded.Too much current on the pump.Pump is delivering at a higher rate than requested.SPM ingredient not available due to too many MicroPumpSPMOccludedTroubles.This trouble is generated by DefaultPumpErrorHandler when it detects a sold out condition on a pump that doesn't have an associated cartridge.SPM pumps did not complete Event sequence: JET_ST_SPM_NOT_COMPLETE(142)SPM Pump is occluded.SPM pump still ON while inactive Event sequence: JET_ST_SPM_ON_WHILE_INACTIVE(141)Pump is too hot to run.Pump is delivering at a lower rate than requested.Trouble that indicates that MSV not ready yetPump is delivering at a higher rate than requested.Trouble that indicates that MSV is sold out.Pump is delivering at a lower rate than requested.Air vent high probe is wet, low is dry.Pump is unable to fill air vent.Result of AirVentProbesDryPumpOp detecting wet probes.Result of AirVentProbesWetPumpOp detecting dry probes.Bubble detect loopback signal lost.Pump is delivering at a higher rate than requested.Base class for various flow errors.Pump is delivering at a lower rate than requested and wants to fold back.Low probe on the air vent is dry.Over delivery alert threshold reached.Overdelivery value is unreasonable.Pump is unable to detect position.Under delivery alert threshold reached.Underdelivery value is unreasonable.CGP Solenoid Failed to OpenDrool Valve Open Failed detected troubleDrool Valve Open Unable to OpenTPM bubble detect.